Negotiable
The date of payment from buyers deliver within days
Beijing
Long-term effective
2022-05-13 10:10
79
Company Profile
Ningbo Yinzhou Chuangshuo Electromechanical Equipment Co., LtdBy certification [File Integrity]
Contact:nbcshuo(Mr.)
Email:
Telephone:
Phone:
Area:Beijing
Address:Beijing
Website:http://www.csds-burner.com/ http://nbcshuo.gzjfsb.com/
A dual-fuel burner or a multifunctional burner is a heating device applied to a hot water boiler, a steam boiler, a hot blast stove and a heat-conducting oil stove.
Using natural gas/methane gas and No. 0 light oil as the main fuel for combustion.
And can be used alternately to deal with energy shortage without affecting factory production.
This series of burners is divided into one-piece forced-draft burners and split-type forced-draft burners.
TLS low power series
TLS Medium Power Series
GI/EMME Medium and Large Power Series
GI/EMME
The output range of the series burners is 407-4650 kW. This series is specially designed for users with large output requirements, and can match various types of boilers with ordinary or pressurized furnaces.
This series of burners is in the "smooth two-stage fire" operation mode. If the PID ratio regulator and probe are installed, it can also be changed to "proportional adjustment" mode. This series of burners can use gas or oil two operation modes, The required operating fuel is changed via the changeover switch. The light oil circuit has its own motor: so the oil pump stops running when using gas to prevent the oil pump from being blocked and prevent the fuel from entering the gas circulation pipeline.
A range of optional accessories and gas manifolds ensure maximum flexibility in burner operation.
The TB series is a split burner, suitable for large-scale applications (such as district heating, hospitals, etc.), and also matched with hot water boilers, steam furnaces and heat transfer oil furnaces, used in food, chemical, textile and other industries.
TB series can provide electronic or mechanical proportional burners according to customer needs. The combustion air temperature of the standard configuration of the TB series can be preheated to 250°C. New adjustable geometry burner enables less than 80mg NOx emissions when burning natural gas
Features:
1. Alternate work of natural gas and light oil
2. Air and fuel are mixed in the combustion head, and ventilation adjusts the combustion head and air volume to obtain the best combustion effect
3. With independent fuel supply pump set
4. Independent gas line
5. Ultraviolet UV flame detection, more stable and safe operation.
6. Gas ratio adjustment operation, adjustment 1:6
7. Two-stage fuel operation
Range load: 1. 163KW-20000KW
Control mode: 2. The burner is divided into two control modes: mechanical proportional adjustment and electronic proportional adjustment
Scope of selection of integrated forced ventilation dual-purpose burners
Model |
Power Range |
Voltage |
Motor Power |
Remark |
TLS28 |
160-325KW |
220V 50/60HZ |
Both oil and gas are two-stage combustion |
|
TLS38 |
232-422KW |
220V 50/60HZ |
Both oil and gas are two-stage combustion |
|
TLS50 |
290-580KW |
380V 50/60HZ |
Both oil and gas are two-stage combustion |
|
TLS70/M |
465-814KW |
380V 50/60HZ |
Oil two sections, gas for proportional adjustment |
|
TLS100/M |
698-1163KW |
380V 50/60HZ |
Oil two sections, gas for proportional adjustment |
|
TLS130/M |
930-1395KW |
380V 50/60HZ |
Oil two sections, gas for proportional adjustment |
|
TLS190/M |
1100-2150KW |
380V 50/60HZ |
Oil two sections, gas for proportional adjustment |
|
TLS250/M |
1230-2462KW |
380V 50/60HZ |
Oil two sections, gas for proportional adjustment |
|
GI/EMME3000 |
1744-3488KW |
380V 50/60HZ |
Oil two sections, gas for proportional adjustment |
|
GE/EMME4500 |
2350-4650KW |
380V 50/60HZ |
Oil two sections, gas for proportional adjustment |
Selection range of split forced ventilation dual-purpose burners
Model |
Power Range |
Voltage |
Motor Power |
Remark |
TB1LSM |
750-1200KW |
220V 50/60HZ |
3.7 KW |
Both oil and gas are two-stage combustion |
TB2LSM |
780-2300KW |
220V 50/60HZ |
5.5KW |
Both oil and gas are two-stage combustion |
TB3LSM |
2000-3800KW |
220V 50/60HZ |
11KW |
Both oil and gas are two-stage combustion |
TB4LSM |
2500-5000KW |
220V 50/60HZ |
15KW |
Oil two sections, gas for proportional adjustment |
TB6LSM |
4000-7800KW |
220V 50/60HZ |
18.5KW |
Oil two sections, gas for proportional adjustment |
TB9LSM |
5000-9500KW |
220V 50/60HZ |
24KW |
Oil two sections, gas for proportional adjustment |
TB12LSM |
7000-12500KW |
220V 50/60HZ |
37KW |
Oil two sections, gas for proportional adjustment |
TB16LSM |
8000-16000KW |
220V 50/60HZ |
45KW |
Oil two sections, gas for proportional adjustment |
TB20LSM |
9500-20000KW |
220V 50/60HZ |
55KW |
Oil two sections, gas for proportional adjustment |
http://www.csds-burner.com/